Roof systems · 5 min read · Updated November 17, 2026
What's the best roofing material for hail in North Texas?
Every roofing material can be damaged by big enough hail. The question is which one gives you the best protection for the money in a place where hail comes almost every year. Here's how the common choices compare for a Dallas–Fort Worth home.
The short answer
For most DFW homes, the best value is an asphalt shingle roof with a Class 4 impact rating. It resists the hail that ruins ordinary shingles, crews and adjusters know it well, and some insurers discount it. Standing seam metal is tougher still, but it costs more and can dent. Tile and slate are heavy and can crack under large hail.
How do the common roofing materials compare for hail?
What each one means for a North Texas roof:
- Architectural asphalt shingles: the most common roof in DFW and the lowest cost. Most carry a lower impact rating or none, so large hail can bruise or crack them.
- Class 4 impact-resistant asphalt shingles: passed UL 2218's 2-inch steel ball test. They cost more than standard shingles, and some Texas insurers offer a premium discount for them.
- Standing seam metal: very durable and long-lived, and many panels carry a Class 4 rating. Hail can still leave dents that don't leak, so ask your insurer how it treats cosmetic dents on a metal roof.
- Concrete tile, clay tile and slate: heavy and long-lasting, but rigid materials can crack under large hail. If you want one, ask for a product rated Class 4 under FM 4473, the impact test for rigid roofing.
Why the rating matters more than the material name
Two shingles that look alike can perform very differently in hail. The impact class on the product's label tells you what it was tested to survive: UL 2218 for shingles and panels, FM 4473 for rigid materials like tile. When you compare quotes, compare the rated product, not just "architectural shingle" or "metal."
Does the rest of the roof system matter?
Yes. Underlayment, flashing, ventilation and the decking under the shingles decide whether a roof that takes a hit still keeps water out. A tough shingle on a poorly built system won't save you. Our guide to what goes into a roof system covers what to ask.
What PowerEdge installs
On homes we install GAF and Owens Corning asphalt shingle roofs, with Class 4 impact-resistant lines from both on request. On commercial buildings we install standing seam metal and TPO flat roofs. Every inspection is free, and you get the verdict in writing, including when your roof is fine.
Sources
Keep reading
- How much does a roof replacement cost in Dallas–Fort Worth? →
- Hail damage roof insurance claims in Texas: the honest guide →
- Is my roofer licensed in Texas? →
- How roof deductible financing works in Texas →
- Are Class 4 impact-resistant shingles worth it in North Texas? →
- What goes into a roof system, and what should you ask your roofer? →
- Roof warranties explained: manufacturer vs. workmanship →